Power Amplifiers for Radio Relay Communication Lines

NameDigOperating frequency range
Instruments for equipment GTT-70/6 (RF6000)
1Microwave power amplifier UM6-1I, M6-3I, UM6-5I, UM6-10I1 to 10 watts5,67-6,17 GHz
Instruments for equipment GTT-70/4 (RF4000)
2Microwave power amplifier UM4-1I, M4-3I, UM4-5I, UM4-10I, UM4-15I1 to 15 watts3,4-3,9 GHz
Instruments for equipment GTT-70 (SRF-8/960)
3Microwave power amplifier UM8-1I, UM8-3I, UM8-5I, UM8-10I1 to 10 watts7,9-8,4 GHz
Devices for equipment “course-6”
4Microwave power amplifier UM6-1IK, UM6-3IK, UM6-5IK, UM6-10IK1 to 10 watts5,67-6,17 GHz
Devices for the equipment “course-4” and “course-4m”
5Microwave power amplifier UM4-1IK, M4-3IK, UM4-5IK, UM4-10IK, UM4-15IK1 to 15 watts3,4-3,9 GHz
Devices for equipment “course-8”
6Microwave power amplifier UM8-1IK, UM8-3IK, UM8-5IK, UM8-10IK1 to 10 watts7,9-8,4 GHz
Devices for equipment “rakita-8”
7Microwave power amplifier UM8-1IRK, UM8-3IRK, UM8-5IRK, UM8-10IRK1 to 10 watts7,9-8,4 GHz
Devices for dawn equipment
8Microwave power amplifier UM4-1IRS, UM4-3IRS, UM4-5IRS, UM4-10IRS1 to 10 watts3,4-3,9 GHz
Devices for equipment “rainbow-4”
9Microwave power amplifier UM4-1IRD, UM4-3IRD, UM4-5IRD1 to 5 W3,4-3,9 GHz
Devices for equipment “rainbow-6”
10Microwave power amplifier UM6-1IRD, UM6-3IRD, UM6-5IRD1 to 5 watts5,67-6,17 GHz
Instruments for friendship-6 equipment
11Microwave power amplifier UM6-1ID, UM6-3ID, UM6-5ID, UM6-10ID1 to 10 watts5,67-6,17 GHz
Devices for equipment “sunrise”
12Microwave power amplifier UM4-1IV, UM4-3IV, UM4-5IV1 to 5 watts3,4-3,9 GHz
Devices for the equipment “Teletra”
13Microwave Power Amplifier UM2-3ITL3,5 W1,695-2,1 GHz
14Microwave power amplifier UM4-1ITL, UM4-3ITL, UM4-5ITL1.2 to 5 watts3,4-3,9 GHz
Devices for the equipment “Thomson-6”
15Microwave power amplifier UM6-1dt, UM6-3dt, UM6-5dt, UM6-10dt (signal transmission with modulation of 128 cameras = 10e-6)Psat = from 1 to 10 watts5,67-6,17 GHz
Instruments for the P600-2MV equipment
16UM4-1IR600 microwave power amplifier, UM4-3IR600, UM4-5IR6001 to 5 watts3,4-3,6 GHz
Instruments for tropospheric communication equipment
17UM1.5-10I microwave power amplifier10 W1,4-1,55 GHz
18Microwave power amplifier UM2,4-10I10 W2,3-2,5 GHz
Devices for troposphere communication equipment
19Microwave power amplifier UM1-50ITF, UM1-300ITF50 to 300 watts0,815-0,865 GHz
0,965-1,015 GHz
Instrumentation Equipment mmds
20Microwave power amplifier UM2.6-25IM, UM2.6-100IM25 to 100 watts2,5-2,7 GHz

Terms of Use:

Ambient operating temperature: 278 К (5оС) … 313 К (40оС),

Ambient temperature limit inoperative: 223 К (- 50оС) … 333 К (60оС),

Relative humidity no more than 98% at a temperature no more 298 К (25оС),

Atmospheric reduced pressure 1.2 * 10 * 4 PA (90 mmHg) during air transportation.

Reliability indicators:

MTBF, at least: 20,000.0 hours

Service life: 10 years

Warranty period: 3 years.